Lubrication System Selection
Depending upon the required lubrication system, a compatible pump and distribution equipment must be selected to enable correct operation to take place.
Mixing pumps and distribution equipment from different types of systems may cause faults.
By referring to the chart below, an appropriate lubrication system and components for a specific requirement can be identified.
SHOWA Lubrication System Chart
Distribution Equipment / Applicable Pump Units
Distribution Equipment | Description | Application Pump Units | ||
---|---|---|---|---|
Measures exact amounts of oil to be distributed, which is not affected by pressure or viscosity. The Dester plunger will discharge its pre-measured volume of oil by utilizing the direct pressure produced by the pump. Pumps will need to possess a pressure displacement mechanism, enabling the Dester plungers to replenish itself with oil. |
Motorized | MLA*W, MLB*W Models | Intermittent Type + Pressure Displacement |
|
LCA3 Model | ||||
LCA4 Model | ||||
LCB3 Model | ||||
Measures exact amounts of oil to be distributed, which is not affected by pressure or viscosity. The Dester Block will discharge its pre-measured volume of oil by utilizing the pressure produced by the internal spring. The DSBs are suited for lower pressure systems, as discharge is induced by a spring and not by the pump’s discharge pressure. |
LCB3 TMS Model | |||
LCB4 Model | ||||
LCB5 Model | ||||
Pneumatic | HP*W* Model (Contact Showa) |
|||
Manual | LAW* Model | |||
The DG piston distributors, will discharge a pre-measured amount of grease, utilizing the pump’s discharge pressure. Pumps will require a pressure displacement mechanism to enable the DG to replenish itself with grease. To be used in conjunction with GD distribution blocks to simplify installation. |
Motorized | GPMW30 Model | ||
Manual | GPHW01 Model | |||
Measures exact amounts of lubricant to be distributed, which is not affected by pressure or viscosity. The Dester G will discharge measured volumes of grease through each port, one after the other in sequence (progressively). Blocks with differing discharge volumes selectable. A visual indicator pin or a limit switch option is available. |
Motorized | MHG4 Model | Continuous Type + Progressive discharge |
|
MHG7 Model | ||||
GPM101 Model | ||||
Measures exact amounts of lubricant to be distributed, which is not affected by pressure or viscosity. The Dester G will discharge measured volumes of grease through each port, one after the other in sequence (progressively). PSG attachments can be attached to combine ports. A Visual indicator pin or a limit switch option is available. |
GPM102 Model | |||
Manual | SHG Model | |||
GPH Model | ||||
The Flow Proper Unit (Meter Unit) will apply flow resistance according to the number displayed on the unit. Oil from the pump unit can be distributed proportionally by applying various levels of resistance at lubrication points. The unit is best suited with accumulative pressure type pumps (no pressure displacement mechanisms). |
Motorized | YMAS Model | Intermittent Accumulative Pressure Type |
|
SMD Model | ||||
SSMA Model | ||||
MY6 Model | ||||
MV Model | Continuous | |||
Manual | LD Model | Intermittent Accumulative |
||
EA & HLA7 Models | ||||
The Continuous Unit applies flow resistance according to the number displayed on the unit. By applying various levels of resistance at junctions or lubrication points, the lubricant can be distributed proportionally. Unlike the PSS range, these units possess no internal check valves. |
Motorized | MLA, MLC, MLD Models | Continuous Type |
|
MHG4, MHG7 Models | ||||
GPM101, GPM102 Models | ||||
Manual | SHG Model | |||
GPH Model | ||||
Dester Valve distribution junctions possess adjustable flow-rate valves on each port, allowing simple flow adjustments to be performed. No replacement or additional parts are required for basic adjustments and modifications in lubrication output, making system design, installation and modifications simple to perform. VA & VB units are suited for both the intermittent and continuous type resistance systems and can be used in Total Loss or Circulating lubrication systems. (Please enquire for usage conditions when utilizing the Dester Valves in conjunction with SMD, SSMA or grease pumps) |
Motorized | YMAS Model | Intermittent Accumulative Pressure Type |
|
SMD Model | ||||
SSMA Model | ||||
MLA, MLC, MLD Models | Continuous Type |
|||
Manual | LA Model | Intermittent Direct Pressure |
||
HLA7 Model | Intermittent Accumulative Pressure Type |
|||
LD Model | ||||
EA Model | ||||
Motorized | MHG4, MHG7 Models | Continuous Type |
||
GPM101, GPM102 Models | ||||
Manual | SHG Model | |||
GPH Model |