Piston Distributor DG

Form code

DG

Specifications

MODEL CODE Discharge
Volume
(c㎥/st)
Activating
Pressure
(Mpa)
Return
Pressure
(Mpa)
Connection
Size
(GD Blocks)
Connection
Size
(Outlet Port)
Recommended
Piping Size
Size
Reference
(Diagram)
Applicable
Grease
Grade
Main Branch
DG3 0.03 Min.
2.5
Max.Usage
10 (*a)
1.2 R1/8 M8 × 1.0 φ6+
Interior
φ4
Exterior
Diag. 1 NLGI
No.000~2
DG5 0.05
DG10 0.1
DG20 0.2
DG30 0.3 Diag. 2
DG50 0.5
DG100 1.0 Diag. 3
DG150 1.5

※(*a)   The GPMW grease pump’s default discharge pressure is 8MPa, while the GPHW hand pumps are 10MPa.

※”Return Pressure” refers to the internal pressure of the distribution pipes, which it must drop below to enable the pistons to replenish themselves  between  discharges.      Failing  to  drop  the  distribution  system’s  pressure  below 1.2MPa, prior to the succeeding discharge, will lead to irregular volumes of grease to be discharged.

 

Drawing

DG_drawing_01_en

Products Download