LCB3 (TMS) Lubrication Unit

  • TMS compliant – volumetric type automatic pump unit
  • Discharge frequency can be controlled by timer or impulse
  • Array of functions and features to suit various lubrication system requirements

 

The LCB3 TMS model lubrication unit possesses a controller which complies to the TMS standards.
The  unit’s  operation  (discharge  frequency  or  intermittence)  can  be  controlled  by  either  an
intermittence timer or an impulse count timer and may also be controlled from an external source.
Possessing a pressure switch & float switch, effective lubrication management can be undertaken.

Form code

LCB3-TMS_modelName_en

Specifications

MODEL CODE Intermittence
(Impulse or mins)
Discharge Vol.
(L / minute)
Discharge
Pressure
Tank
Capacity
(L)
Effective
Tank
Capacity  (L)
Viscosity
Range
Warning
Triggers
LCB301 2, 4, 6, 8, 16, 24,
32, 48, 64, 128
(Can be modified)
0.1L – 50Hz
0.12L – 60Hz
1.5MPa 3.4 2 50~800
m㎡/s
Pressure surge,
pressure loss,
low oil levels
LCB302 5.5 4.4
LCB303 14.4 10.9

※Oil can be discharged by pressing the “Instant button”.   The pump will continue to operate until the button is released.

 

MOTOR SPECIFICATION

Voltage & Freq. 100V 50Hz 100V 60Hz 200V 50Hz 200V 60Hz
Current (A) 1.6A 1.3A 0.9A 0.7A
Output & Poles 17W × 2P
Operation Max. 5mins with resting time of operation × 2

※E – type insulation

※E – type insulationSpecified intermittence can be increased by × 2, × 3 or × 4

 

Drawing

LCB3-TMS_drawing_01_en

Products Download